If you’re holding an ILS Laboratories certificate and want to know whether it matches your vial, you can check it yourself. Find the access code printed under the QR code and in the footer, enter it at ILS Laboratories verification page, and compare the lab’s record with your lot number, product name and amount. For the Merit Sciences BPC-157 / TB-500 batch used as the example here, the lab’s own record is the version to trust, not a PDF copy.
This is research-use-only material. The record makes no statement that it is safe for people, and nothing on this page covers human use. If you’re thinking about putting any peptide in your body, talk to a clinician first.

Where is the access code on the certificate?
Every ILS certificate carries a 7- to 8-character access code, printed under the QR code and again in the footer. The example here is certificate COA-2026-Z6RSEN, issued 08/01/2026 by ILS Laboratories LLC in San Diego, California, and signed by Dr. Greg Kalyuzhny, the lab director. Its access code is PXJJ5YK6.
Scanning the QR code on a PDF copy won’t get you to the record. On this batch, it opens the lab’s portal home page. Type the access code in yourself.
How do I look up the record?
- Go to ILS Laboratories verification page.
- Enter the access code. The lab’s own page shows the record from its database.
- Match the lot number on your vial to the lot on the record. For this batch, that’s LOT2026-06-0001.
- Match the product and amount to the label. This batch is BPC-157 / TB-500, labeled 20 mg, in a 3 mL vial.
- Read the record on the lab’s site, not a saved copy.
What does the lab’s record show for this Merit batch?
The record covers the Full QC Panel for lot LOT2026-06-0001. The sample was received 07/14/2026 and analysed 08/01/2026. These are the main results.
| Test | Method | Result in the record |
|---|---|---|
| Purity | RP-HPLC, area normalisation at 214 nm | 99.51% against a spec of at least 95.0%: PASS |
| Net blend peptide content | Reported by the lab (method not stated in the record) | 20.49 mg (labeled 20 mg) |
| BPC-157 | Calculated from total, using the maker’s stated ratio | 10.24 mg |
| TB-500 | Calculated from total, using the maker’s stated ratio | 10.24 mg |
| Identity | HPLC retention time against a reference standard | BPC-157 + TB-500 confirmed |
| Sterility | PCR | No growth: PASS |
| Endotoxin (USP <85>) | Reported as a value | 0.063 EU/mL |
| Fentanyl immunoassay screen | 50 ng/mL cutoff | Not detected |
Heavy metals were tested by ICP-MS under the USP <233> method. The limits are ILS’s internal screening limits for research materials, not a pharmacopeial monograph.
| Metal | Result | Lab limit | Outcome |
|---|---|---|---|
| Arsenic | 0.2 ppm | 1.5 | PASS |
| Cadmium | 0.1 | 0.5 | PASS |
| Lead | 0.32 | 1.0 | PASS |
| Mercury | 0.002 | 1.5 | PASS |
| Chromium | 1.48 | 10.0 | PASS |
What do the tests mean?
Purity
The 99.51% figure is the target peptide as a share of all peptide-related peaks. Non-peptide process impurities are left out of that number, so it measures the peptide against other peptide-related material, not against everything in the vial.
Identity
Identity was confirmed by HPLC retention time against a reference standard. A review of peptide reference standards in Pharmaceutical Research notes that several orthogonal techniques are typically used to confirm a peptide’s chemical identity, including HPLC retention time, NMR, MS and chiral testing. This panel used retention time. Mass-spec identity (LC-MS) was not part of it, and the lab sells it as an add-on.
Sterility
The sterility result is by PCR, with no growth. A culture-based sterility test under USP <71> was not part of this panel. The FDA pharmaceutical microbiology manual says sterility testing follows USP <71> and that its culture incubation runs not less than 14 days. The 21 CFR 610.12 sterility rule accepts both culture-based and non-culture-based methods, as long as the method is validated. That rule is written for licensed biological products, so treat it as a reference point rather than a rule this batch had to meet.
Endotoxin
The endotoxin result is 0.063 EU/mL, reported as a value. ILS says no universal pass/fail limit applies to research-use products, and that the value is below commonly referenced thresholds. The FDA pyrogen and endotoxin guidance says endotoxin limits are worked out with calculations from the USP or AAMI standards, not taken from one fixed table. Read the number itself.
Fentanyl screen
The fentanyl screen is an immunoassay with a 50 ng/mL cutoff, and it was not detected. ILS’s order page lists this screen as included at no cost on every sample. Merit did not add it. Fentanyl test strips are street-drug tools, not lab panels, so these studies only show how immunoassay screens behave in general: in one, a fentanyl test strip false-positive study found methamphetamine, MDMA and diphenhydramine gave false positives at or above 1 mg/mL, and in another, a fentanyl test strip lab-performance study found sensitivity varied from lot to lot. They don’t tell you what this panel found.
What doesn’t the record cover?
- It covers the Full QC Panel only. LC-MS identity, culture sterility under USP <71>, a blind test and reconstitution stability are add-ons a company can choose, and none of them is in this record.
- ILS says it runs a quality management system based on ISO/IEC 17025, and says “Peptide testing is not within any accreditation scope.” So this test is not accredited.
- Sample names, brand and lot numbers come from the submitting company. The record says they are not independently verified.
- The record covers only the sample tested. It is not an evaluation or endorsement of the maker’s processes.
If you need one of those add-ons for a batch, ask the lab whether it was run. The record shows what was run.
How do I compare a seller’s PDF with the lab’s record?
Merit says every batch clears the same panel, and that the certificate is published before the batch can be bought. Merit’s site also says the QR code on each vial label opens its COA library. Those are Merit’s statements. The lab’s record is what you can check directly.
Then compare these points:
- The lot number on your vial should match the lot on the record.
- The product and amount should match the label: BPC-157 / TB-500, 20 mg labeled. The record’s net content is 20.49 mg.
- The per-component split should match the record.
A PDF copy of this batch listed a different split from the lab’s record, as the table shows. Where a PDF and the record differ, go with the record.
| Component | Lab record | PDF copy |
|---|---|---|
| BPC-157 | 10.24 mg | 10.45 mg |
| TB-500 | 10.24 mg | 10.04 mg |
So is a COA legit, and can I verify authenticity?
The check tells you whether the lab holds a record under that access code, and whether the lot, product and amount on it match your vial. It cannot tell you who made the material or how it was handled before it reached you. The record covers only the sample tested, and the names come from the submitting company.
A COA is the lab’s test report for one sample. For a closer look at how a seller’s paperwork fits together, see how to verify a peptide company. For another angle on what a label can and can’t tell you, see male vitality labels and proprietary blends.
This page is from The Nerve & Joint Pain Desk and is not written by ILS Laboratories or Merit Sciences. Merit Sciences sells the batch at meritsciences.com.
By The Nerve & Joint Pain Desk Editorial Team
The source facts for this page were checked by a person on our team on November 19, 2026.